Experimental studies of a thermoelectric current source with an annular thermopile

Authors

  • L.I. Anatychuk 1. Institute of Thermoelectricity of the NAS and MES of Ukraine, 1 Nauky str., Chernivtsi, 58029, Ukraine. 2. Yuriy Fedkovych Chernivtsi National University 2 Kotsiubynskyi str., Chernivtsi, 58012, Ukraine
  • P.D. Mykytiuk 1. Institute of Thermoelectricity of the NAS and MES of Ukraine, 1 Nauky str., Chernivtsi, 58029, Ukraine. 2. Yuriy Fedkovych Chernivtsi National University 2 Kotsiubynskyi str., Chernivtsi, 58012, Ukraine
  • O.Yu. Mykytiuk 1. Institute of Thermoelectricity of the NAS and MES of Ukraine, 1 Nauky str., Chernivtsi, 58029, Ukraine. 2. Yuriy Fedkovych Chernivtsi National University 2 Kotsiubynskyi str., Chernivtsi, 58012, Ukraine

Keywords:

output power, thermoelectric battery, current source, voltage

Abstract

The results of studies of a single-acting thermoelectric current source with an annular thermopile are presented. The research results confirmed the efficiency of current source breadboard models with an annular thermopile and the compliance of their electrical parameters with the requirements of the Performance Specification under Contract 3/2019. Bibl. 2, Fig. 6, Tabl. 1.

References

1. Anatychuk L.I., Mykytiuk P.D. (2019). Design of an annular thermopile for а single acting current source. J.Thermoelectricity, N3.

2. Program and methods of research on a thermoelectric current source with an annular thermopile. Contract 3/2019 of 16.04.2019. Institute of Thermoelectricity.

How to Cite

Anatychuk, L., Mykytiuk, P., & Mykytiuk, O. (2024). Experimental studies of a thermoelectric current source with an annular thermopile. Journal of Thermoelectricity, (2), 75–82. Retrieved from http://jte.ite.cv.ua/index.php/jt/article/view/99

Issue

Section

Thermoelectric products

Most read articles by the same author(s)

<< < 1 2 3 4 5 

Similar Articles

1 2 3 > >> 

You may also start an advanced similarity search for this article.